Nrca guidelines regarding attic ventilation nrca recommends designers provide at least 1 square foot of nfva for every 150 square feet of attic space 1 150 ventilation ratio measured at the attic floor level ceiling.
Attic ventilation requirements irc.
Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.
Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.
Between half and two thirds of the provided ventilation shall be installed at the eaves.
The ventilation openings shall have a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum.
The minimum amount of attic ventilation remains 1 150 1 square foot of net free area for every 150 square feet of attic floor space.
Let owens corning roofing help you calculate exactly how much ventilation you will need for a healthy and balanced attic with our 4 step ventilation calculator.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Ventilation openings shall have a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum.
Attic floor is defined as length x width floor of the attic.
The following are the requirements taken directly from the irc.
Always have a balanced ventilation system.
Vented attics shall have a minimum net free ventilation area at least 1 300 of the area of the vented space.
Also when using a vapor retarder in an attic space irc 2012 limits the net free ventilation reduction from 1 150 to 1 300 for buildings in climate zones 6 7 and 8.
For large volume attics such as where roof slopes.
More ventilation at the soffitsthan at the ridge will allow the attic to be slightly pressurized irc 2012 requirements reflect this approach for best results provide 50 to 75 of ventilation space at the soffits 60 40 is the optimal split.
In no case should the amount of exhaust ventilation exceed the amount of intake ventilation.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
2015 international residential code for attic ventilation air vent inc.